Magnetbetätigt, entlastbare Druckbegrenzung Baugruppe

Function

Function for XRGX: Normally Closed
Normally Closed
Function for XRGX: Normally Open
Normally Open
Port Designators [ + ]
Modifiers Ports
4, 4/S Ports 1 & 2: 1" Code 62; Port G: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
4/M, 4/T Ports 1 & 2: 1" Code 62; Port G: 1/4" BSPP; Mounting Holes: M10 x 1.5-6H x .62 DP;
5, 5/S Ports 1 & 2: 1 1/4" Code 62; Port G: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
5/M, 5/T Ports 1 & 2: 1 1/4" Code 62; Port G: 1/4" BSPP; Mounting Holes: M10 x 1.5-6H x .62 DP;
D, D/S Ports 1 & 2: 3/4" NPTF; Gage Port: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
E, E/S Ports 1 & 2: 1" NPTF; Gage Port: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
F, F/S Ports 1 & 2: 1 1/4" NPTF; Gage Port: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
L, L/S Ports 1 & 2: SAE 12; Gage Port: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
M, M/S Ports 1 & 2: SAE 16; Gage Port: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
N, N/S Ports 1 & 2: SAE 20; Gage Port: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
P, P/S Ports 1 & 2: 1" Code 61; Port G: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
P/M, P/T Ports 1 & 2: 1" Code 61; Port G: 1/4" BSPP; Mounting Holes: M10 x 1.5-6H x .62 DP;
Q, Q/S Ports 1 & 2: 1 1/4" Code 61; Port G: 1/4" NPTF; Mounting Holes: .375 - 16UNC x .62 DP;
Q/M, Q/T Ports 1 & 2: 1 1/4" Code 61; Port G: 1/4" BSPP; Mounting Holes: M10 x 1.5-6H x .62 DP;
W, W/S Ports 1 & 2: 3/4" BSPP; Gage Port: 1/4" BSPP; Mounting Holes: M10 x 1.5-6H x .62 DP;
X, X/S Ports 1 & 2: 1" BSPP; Gage Port: 1/4" BSPP; Mounting Holes: M10 x 1.5-6H x .62 DP;
Y, Y/S Ports 1 & 2: 1 1/4" BSPP; Gage Port: 1/4" BSPP; Mounting Holes: M10 x 1.5-6H x .62 DP;
Technische Eigenschaften [ + ]

Die Ventilkombination bietet zwei Funktionen. Übersteigt der Druck an Anschluss 1 die Ventileinstellung, wird Anschluss 1 (Druckseite) zum Tank (Anschluss 2) entlastet. Mit dem Magnetventil kann das Druckbegrenzungsventil entlastet und die Ventileinstellung auf einen geringen Wert reduziert werden. Die Ventileinheit ist in stromlos geöffneter oder gesperrter Ausführung erhältlich. Stromlos geöffnet (H) bedeutet, dass sich der Druck vor der Bestromung des Magnetventils auf einem niedrigen Niveau befindet. Stromlos gesperrt (C) heißt, dass sich der Druck vorher auf einem hohen Niveau befindet.

  • Diese Ventilkombination eignet sich gut als Pumpenabschalteinheit.
  • Die Bauweise des fernsteuerbaren Druckbegrenzungsventils führt zu einem weichen Druckanstieg. Die Entlastung ist hart.
  • Ab sofort mit Magnetventilen der FLeX-Serie erhältlich. Bitte wählen Sie im Konfigurationsbereich das passende Magnetventil aus.
Technische Daten [ + ]
Gehäusetyp RohrleitungseinbauRohrleitungseinbau
Durchfluss 60 gpm240 L/min.
Anzahl der Montagebohrungen 22
FAQs [ + ]

Es sind genau 250 "SUN" Tropfen in einem cubic inch oder 15 in einem ccm.

Reasons to anodize:

  • To increase corrosion resistance. Sun uses 6061-T651 aluminum. It is one of the most corrosion resistant aluminum alloys there is. Whether or not anodizing improves the corrosion resistance of 6061 aluminum is debatable. We have yet to have a manifold returned because of corrosion.
  • Appearance (color). The 2 colors that would appeal to Sun would be blue or black. Unfortunately these are the colors that are hardest to do consistently.
  • To provide a hard wear surface. Sun does not make parts-in-body valves. The manifold is just plumbing. We don't need a wear surface.
  • Because everyone else does it. Bad reason. 

Reasons to not anodize:

  • Cost. It's another process.
  • Logistics. When you make tens of thousands of manifolds a month and you anodize hundreds, it's a problem. Consistency. See above.
  • Stamping. After a body is anodized you cannot do any more stamping without making a mess.
    Inspection. Have you ever tried to look for burrs in a black anodized body? It's the old blackboard factory at night scenario.
  • Torque. You will experience an increase in breakaway torque when removing items from an anodized manifold.
  • Fatigue life. This is the best reason to not anodize. Fatigue failure is a very complex phenomenon. What it takes to initiate a crack is difficult to predict. What it takes to propagate a crack is readily defined. Anodizing produces a very thin, very hard, and very brittle surface on aluminum. The first time you pressurize an anodized aluminum manifold you have initiated fatigue cracks. Whether or not the stress is enough to propagate the cracks is a matter of pressure and manifold geometry. Anodizing an aluminum manifold grossly reduces the fatigue life by anywhere from 20% to 50%.

Direkt gesteuert Ventile werden genutzt, um Überdruck zu vermeiden und vorgesteuerte Ventile werden genutzt, um einen Druck zu regulieren. Wenn Sie unsicher in Ihrer Entscheidung sind, nehmen Sie ein direkt gesteuertes Ventil. SUNs direkt gesteuerte Ventile sind sehr schnell, schmutzunempfindlich, haltbar und robust. SUNs vorgesteuerte Ventile sind moderat schnell, haben einen geringen Druckanstieg über dem Volumenstrom und sind einfach einzustellen.

Info [ + ]
  • Wichtig: Beachten Sie bitte sorgfältig die maximalen Systemdrücke, denen das Gehäuse ausgesetzt ist. Der Druckbereich ist hauptsächlich abhängig vom Gehäusematerial. Anschlussart und Anschlussgröße sind von sekundärer Bedeutung. Zum Beispiel sind Aluminiumgehäuse nur bis zu einem Systemdruck bis 210 bar zugelassen, unabhängig von Anschlussart und -größe.
  • Für detailliertere Informationen bezüglich der Ventile in dieser Zusammenstellung klicken Sie bitte auf den Modelcode im Bereich Included Components.
Zusätzliche Hilfsmittel [ + ]
Spuleninfo [ + ]

No coil selected.