Magnetbetätigt, gegenseitige Druckbegrenzung Baugruppe

Function

Function for XREL: Normally Open
Normally Open
Port Designators [ + ]
Modifiers Ports
B, B/S Ports 1 & 2: 3/8" NPTF; Gage Ports: 1/4" NPTF; Port V: 1/4" NPTF;
C, C/S Ports 1 & 2: 1/2" NPTF; Gage Ports: 1/4" NPTF; Port V: 1/4" NPTF;
D, D/S Ports 1 & 2: 3/4" NPTF; Gage Ports: 1/4" NPTF; Port V: 1/4" NPTF;
E, E/S Ports 1 & 2: 1" NPTF; Gage Ports: 1/4" NPTF; Port V: 1/4" NPTF;
I, I/S Ports 1 & 2: SAE 6; Gage Ports: 1/4" NPTF; Port V: SAE 6;
J, J/S Ports 1 & 2: SAE 8; Gage Ports: 1/4" NPTF; Port V: SAE 6;
K, K/S Ports 1 & 2: SAE 10; Gage Ports: 1/4" NPTF; Port V: SAE 6;
L, L/S Ports 1 & 2: SAE 12; Gage Ports: 1/4" NPTF; Port V: SAE 6;
M, M/S Ports 1 & 2: SAE 16; Gage Ports: SAE 6; Port V: SAE 6;
U, U/S Ports 1 & 2: 3/8" BSPP; Gage Ports: 1/4" BSPP; Port V: 1/4" BSPP;
V, V/S Ports 1 & 2: 1/2" BSPP; Gage Ports: 1/4" BSPP; Port V: 1/4" BSPP;
W, W/S Ports 1 & 2: 3/4" BSPP; Gage Ports: 1/4" BSPP; Port V: 1/4" BSPP;
X, X/S Ports 1 & 2: 1" BSPP; Gage Ports: 1/4" BSPP; Port V: 1/4" BSPP;
Technische Eigenschaften [ + ]

Diese Ventilkombination bietet Entlastung und Doppeldruckbegrenzung. Die Anschlüsse 1 und 2 werden vor Überdruck geschützt. Das Magnetventil schaltet beide Druckbegrenzungsventile. Diese Ventileinheit ist in stromlos geöffneter oder gesperrter Ausführung erhältlich. Stromlos geöffnet bedeutet, dass sich der Druck vor der Bestromung des Magnetventils auf einem niedrigen Niveau befindet. Stromlos gesperrt heißt, dass sich der Druck vorher auf einem hohen Niveau befindet.

  • Beide Anschlüsse mit der Beschriftung 1 sind verbunden, ebenso die mit der Beschriftung 2. Das Druckbegrenzungsventil, das sich auf der Seite 1 befindet, regelt den Druck an Anschluss 2 und umgekehrt.
  • Diese Ventilkombination eignet sich gut als Pumpenabschalteinheit.
  • Die Bauweise des fernsteuerbaren Druckbegrenzungsventils führt zu einem weichen Druckanstieg. Die Entlastung ist hart.
  • Ab sofort mit Magnetventilen der FLeX-Serie erhältlich. Bitte wählen Sie im Konfigurationsbereich das passende Magnetventil aus.
Technische Daten [ + ]
Gehäusetyp RohrleitungseinbauRohrleitungseinbau
Durchfluss 30 gpm120 L/min.
Montagebohrungsdurchmesser .42 in.10,7 mm
Montagebohrungstiefe durchgehenddurchgehend
Anzahl der Montagebohrungen 22
FAQs [ + ]

Reasons to anodize:

  • To increase corrosion resistance. Sun uses 6061-T651 aluminum. It is one of the most corrosion resistant aluminum alloys there is. Whether or not anodizing improves the corrosion resistance of 6061 aluminum is debatable. We have yet to have a manifold returned because of corrosion.
  • Appearance (color). The 2 colors that would appeal to Sun would be blue or black. Unfortunately these are the colors that are hardest to do consistently.
  • To provide a hard wear surface. Sun does not make parts-in-body valves. The manifold is just plumbing. We don't need a wear surface.
  • Because everyone else does it. Bad reason. 

Reasons to not anodize:

  • Cost. It's another process.
  • Logistics. When you make tens of thousands of manifolds a month and you anodize hundreds, it's a problem. Consistency. See above.
  • Stamping. After a body is anodized you cannot do any more stamping without making a mess.
    Inspection. Have you ever tried to look for burrs in a black anodized body? It's the old blackboard factory at night scenario.
  • Torque. You will experience an increase in breakaway torque when removing items from an anodized manifold.
  • Fatigue life. This is the best reason to not anodize. Fatigue failure is a very complex phenomenon. What it takes to initiate a crack is difficult to predict. What it takes to propagate a crack is readily defined. Anodizing produces a very thin, very hard, and very brittle surface on aluminum. The first time you pressurize an anodized aluminum manifold you have initiated fatigue cracks. Whether or not the stress is enough to propagate the cracks is a matter of pressure and manifold geometry. Anodizing an aluminum manifold grossly reduces the fatigue life by anywhere from 20% to 50%.

Direkt gesteuert Ventile werden genutzt, um Überdruck zu vermeiden und vorgesteuerte Ventile werden genutzt, um einen Druck zu regulieren. Wenn Sie unsicher in Ihrer Entscheidung sind, nehmen Sie ein direkt gesteuertes Ventil. SUNs direkt gesteuerte Ventile sind sehr schnell, schmutzunempfindlich, haltbar und robust. SUNs vorgesteuerte Ventile sind moderat schnell, haben einen geringen Druckanstieg über dem Volumenstrom und sind einfach einzustellen.

Es sind genau 250 "SUN" Tropfen in einem cubic inch oder 15 in einem ccm.

Info [ + ]
  • Wichtig: Beachten Sie bitte sorgfältig die maximalen Systemdrücke, denen das Gehäuse ausgesetzt ist. Der Druckbereich ist hauptsächlich abhängig vom Gehäusematerial. Anschlussart und Anschlussgröße sind von sekundärer Bedeutung. Zum Beispiel sind Aluminiumgehäuse nur bis zu einem Systemdruck bis 210 bar zugelassen, unabhängig von Anschlussart und -größe.
  • Für detailliertere Informationen bezüglich der Ventile in dieser Zusammenstellung klicken Sie bitte auf den Modelcode im Bereich Included Components.
Zusätzliche Hilfsmittel [ + ]
Spuleninfo [ + ]

No coil selected.