Port Designators [ + ]
Modifiers Ports
E, E/S Ports P, T, & SYS 1: 1" NPTF; Port SYS 2: 3/4" NPTF; Port G: 1/4" NPTF; Ports D & AUX: 3/8" NPTF; Mounting Holes: .375 - 16UNC x .88 DP;
F, F/S Ports P, T, & SYS 1: 1 1/4" NPTF; Port SYS 2: 1" NPTF; Port G: 1/4" NPTF; Ports D & AUX: 3/8" NPTF; Mounting Holes: .375 - 16UNC x .88 DP;
M, M/S Ports P, T, & SYS 1: SAE 16; Port SYS 2: SAE 12; Port G: SAE 4; Ports D & AUX: SAE 6; Mounting Holes: .375 - 16UNC x .88 DP;
N, N/S Ports P, T, & SYS 1: SAE 20; Port SYS 2: SAE 16; Port G: SAE 6; Ports D & AUX: SAE 6; Mounting Holes: .375 - 16UNC x .88 DP;
X, X/S Ports P, T, & SYS 1: 1" BSPP; Port SYS 2: 3/4" BSPP; Port G: 1/4" BSPP; Ports D & AUX: 3/8" BSPP; Mounting Holes: M10 x 1.5-6H x .88 DP;
Y, Y/S Ports P, T, & SYS 1: 1 1/4" BSPP; Port SYS 2: 1" BSPP; Port G: 1/4" BSPP; Ports D & AUX: 3/8" BSPP; Mounting Holes: M10 x 1.5-6H x .88 DP;
Technische Eigenschaften [ + ]

Diese Ventilkombination erlaubt das Aufladen eines Speichers mittels einer Konstantpumpe. Wenn der Druck den Einstellwert des Ventils erreicht, wird die Pumpe entlastet. Wenn der Druck auf den Wert abfällt, der durch die vorgegebene Hysterese des Vorsteuerventils bestimmt ist, wird die Pumpe zugeschaltet, um den Speicher aufzuladen. Das fernsteuerbare Druckbegrenzungsventil erfüllt zwei Funktionen, eine Entlastung der Pumpe über den Hauptkolben und als eine System Druckbegrenzung. Diese Ventilkombination hat eine zusätzliche Besonderheit: eine einfache Schaltung entlastet die Pumpe ohne Schaltschlag.

  • Zum stabilen Betrieb dieser Ventilkombination sollte die Leckölabführung separat sein, um eine Beeinflussung durch den Staudruck in der Tankleitung zu vermeiden.
  • Hinweis: Bei der Auswahl des Einstellbereichs ist Vorsicht geboten. Differenzen in Druck und Volumenstrom können leicht das Schaltverhalten der Ladeventile beeinflussen. Geringe Arbeitsdrücke verbunden mit geringen Volumenströmen führen zu einer sehr geringen Differenz zwischen dem Zu- und Abschaltdruck. In diesen Fällen ist eine sehr genaue Auslegung des hydraulischen Schaltkreises erforderlich. Hohe Volumenströme bedeuten normalerweise hohe Druckgefälle, die von dem Druckgefälle, mit dem das Ladeventil arbeitet, abgezogen werden müssen.
  • Der Druckeinstellwert und der sich ergebende Schließdruck sind abhängig vom Anschluss 1 des QPA* Vorsteuerventils. Durch den vom Volumenstrom verursachten Druckabfall erhöht sich der Pumpendruck, aber der Speicherdruck wird geringer.
  • Die Anschlüsse dieser Ventilkombination sind groß im Vergleich zu der Kapazität. Damit möchte man erreichen, dass die Verrohrung entsprechend groß gewählt wird, um volumenbedingte Druckverluste zu minimieren.
  • Die konstruktive Ausführung des Vorsteuerventilkolbens erlaubt ein konstantes Differenzial, da das Flächenverhältnis durch unterschiedliche Durchmesser am Kolben erreicht wird und sich nicht durch Gebrauch abnutzt oder ändert.
  • Die Einstellung des Vorsteuer-Speicherladeventils muss unter der pumpenseitigen Druckbegrenzungseinstellung sein, sonst könnte starke Erhitzung die Folge sein .
  • Das Druckbegrenzungsventil in dieser Ventilkombination hat die Funktion, Druckspitzen zu verhindern. Es ist über der höchsten Einstellung des Vorsteuerventils eingestellt und ist mit einem Verstellschutz versehen.
Technische Daten [ + ]
Gehäusetyp RohrleitungseinbauRohrleitungseinbau
Durchfluss 80 gpm320 L/min.
Anzahl der Montagebohrungen 33
FAQs [ + ]

Reasons to anodize:

  • To increase corrosion resistance. Sun uses 6061-T651 aluminum. It is one of the most corrosion resistant aluminum alloys there is. Whether or not anodizing improves the corrosion resistance of 6061 aluminum is debatable. We have yet to have a manifold returned because of corrosion.
  • Appearance (color). The 2 colors that would appeal to Sun would be blue or black. Unfortunately these are the colors that are hardest to do consistently.
  • To provide a hard wear surface. Sun does not make parts-in-body valves. The manifold is just plumbing. We don't need a wear surface.
  • Because everyone else does it. Bad reason. 

Reasons to not anodize:

  • Cost. It's another process.
  • Logistics. When you make tens of thousands of manifolds a month and you anodize hundreds, it's a problem. Consistency. See above.
  • Stamping. After a body is anodized you cannot do any more stamping without making a mess.
    Inspection. Have you ever tried to look for burrs in a black anodized body? It's the old blackboard factory at night scenario.
  • Torque. You will experience an increase in breakaway torque when removing items from an anodized manifold.
  • Fatigue life. This is the best reason to not anodize. Fatigue failure is a very complex phenomenon. What it takes to initiate a crack is difficult to predict. What it takes to propagate a crack is readily defined. Anodizing produces a very thin, very hard, and very brittle surface on aluminum. The first time you pressurize an anodized aluminum manifold you have initiated fatigue cracks. Whether or not the stress is enough to propagate the cracks is a matter of pressure and manifold geometry. Anodizing an aluminum manifold grossly reduces the fatigue life by anywhere from 20% to 50%.

Direkt gesteuert Ventile werden genutzt, um Überdruck zu vermeiden und vorgesteuerte Ventile werden genutzt, um einen Druck zu regulieren. Wenn Sie unsicher in Ihrer Entscheidung sind, nehmen Sie ein direkt gesteuertes Ventil. SUNs direkt gesteuerte Ventile sind sehr schnell, schmutzunempfindlich, haltbar und robust. SUNs vorgesteuerte Ventile sind moderat schnell, haben einen geringen Druckanstieg über dem Volumenstrom und sind einfach einzustellen.

Es sind genau 250 "SUN" Tropfen in einem cubic inch oder 15 in einem ccm.

Info [ + ]
  • Wichtig: Beachten Sie bitte sorgfältig die maximalen Systemdrücke, denen das Gehäuse ausgesetzt ist. Der Druckbereich ist hauptsächlich abhängig vom Gehäusematerial. Anschlussart und Anschlussgröße sind von sekundärer Bedeutung. Zum Beispiel sind Aluminiumgehäuse nur bis zu einem Systemdruck bis 210 bar zugelassen, unabhängig von Anschlussart und -größe.
  • Für detailliertere Informationen bezüglich der Ventile in dieser Zusammenstellung klicken Sie bitte auf den Modelcode im Bereich Included Components.
Zusätzliche Hilfsmittel [ + ]